Hybralox
HybraloxTM is the trade name for several series of hybrid Alumina-loaded glasses developed to be harder, stronger, and to have a higher thermal conductivity than normal sealing glasses.
HybraloxTM is self glazing and can be metallized. Compared to Alumina ceramic, Hybralox tooling costs are often lower.
HybraloxTM preforms are now being used for a wide variety of integrated circuit seals or as a replacement for glass-to-metal or ceramic-to-metal seals.
Four HybraloxTM Grades are available:
HybraloxTM 5000 Series
Seals directly to itself or to Kovar without metallizing
HybraloxTM 6000 Series
Seals Kovar to Alumina bases
HybraloxTM 7000 Series
Used both for Kovar to Kovar, and Kovar to Alumina bases
HybraloxTM 9000 Series
Used for compression seals
| Units | Property/Material | Hybralox TM Data | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Hybralox TM | 5000 Series | 6000 Series | 7000 Series | 9000 Series | ||||||
| - | Material | *Base Glass | 5115 | 5125 | *Base Glass | 6125 | *Blase Glass | 7125 | *Base Glass | 9005 |
| % | Alumina Loading | 0 | 15 | 25 | 0 | 25 | 0 | 25 | 0 | 5 |
| x 10 -7/°C | C.T.E. (0-300°C) | 47 | 50 | 52 | 56 | 61 | 51 | 56 | 91 | 92 |
| g/cc | Density | 2.27 | 2.31 | 2.44 | 2.28 | 2.42 | 2.22 | 2.42 | 2.60 | 2.52 |
| °C | Softening Point | 712 | 712 | 712 | 710 | 710 | 740 | 740 | 650 | 650 |
| °C | Working Point | 1010 | 1020 | 1020 | 990 | 1010 | 1000 | 1020 | 950 | 950 |
| - | Dielectric Constant | 5.1 1 MHz R.T. | 5.8 100KHz 110°C | 6.4 100 KHz 110°C | - | 5.7 100 KHz 110°C | - | 6.3 100KHz 110°C | 6.5 1 MHz R.T. | - |
| - | Dissipation Factor | .0015 1 MHz R.T. | .005 100 KHz 110°C | .004 100 KHz 110°C | - | .001 100 KHz 110°C | - | .005 100 KHz 110°C | - | - |
| - | Volume Resistivity | 9.2 250°C | 11.9 110°C | 12.0 110°C | - | 11.7 110°C | - | 12.5 110°C | 8.0 250°C | - |
*Base glass properties are values reported by the glass manufacturer, measured on bulk glass materials.
GBC Materials makes no warranty express or implied concerning the use of this product. Purchaser assumes all risk of use or handling whether or not in accordance with directions or suggestions, or used alone or in combination with other products.